CVE-2017-5144
•
published on February 13, 2017
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. The access control flaw allows access to most application functions without authentication.
-
CVE-2017-5145
•
published on February 13, 2017
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Successful exploitation of this CROSS-SITE REQUEST FORGERY (CSRF) vulnerability can allow execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
-
CVE-2017-5146
•
published on February 13, 2017
An issue was discovered in Carlo Gavazzi VMU-C EM prior to firmware Version A11_U05, and VMU-C PV prior to firmware Version A17. Sensitive information is stored in clear-text.
-
CVE-2017-5151
•
published on February 13, 2017
An issue was discovered in VideoInsight Web Client Version 6.3.5.11 and previous versions. A SQL Injection vulnerability has been identified, which may allow remote code execution.
-
CVE-2017-5152
•
published on February 13, 2017
An issue was discovered in Advantech WebAccess Version 8.1. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access pages unrestricted (AUTHENTICATION BYPASS).
-
CVE-2017-5153
•
published on February 13, 2017
An issue was discovered in OSIsoft PI Coresight 2016 R2 and earlier versions, and PI Web API 2016 R2 when deployed using the PI AF Services 2016 R2 integrated install kit. An information exposure through server log files vulnerability has been identified, which may allow service account passwords to become exposed for the affected services, potentially leading to unauthorized shutdown of the affected PI services as well as potential reuse of domain credentials.
-
CVE-2017-5154
•
published on February 13, 2017
An issue was discovered in Advantech WebAccess Version 8.1. To be able to exploit the SQL injection vulnerability, an attacker must supply malformed input to the WebAccess software. Successful attack could result in administrative access to the application and its data files.
-
CVE-2017-5155
•
published on February 13, 2017
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
-
CVE-2017-5157
•
published on February 13, 2017
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
-
CVE-2017-5159
•
published on February 13, 2017
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
-
CVE-2017-5161
•
published on February 13, 2017
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element (DLL Hijacking) vulnerability has been identified. Exploitation of this vulnerability could give an attacker access to the system with the same level of privilege as the application that utilizes the malicious DLL.
-
CVE-2017-5162
•
published on February 13, 2017
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
-
CVE-2017-5163
•
published on February 13, 2017
An issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal.
-
CVE-2017-5164
•
published on February 13, 2017
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
-
CVE-2017-5165
•
published on February 13, 2017
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
-
CVE-2017-5166
•
published on February 13, 2017
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
-
CVE-2017-5167
•
published on February 13, 2017
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
-
CVE-2017-5168
•
published on February 13, 2017
An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Path Traversal vulnerabilities have been identified. The flaws exist within the ActiveMQ Broker service that is installed as part of the product. By issuing specific HTTP requests, if a user visits a malicious page, an attacker can gain access to arbitrary files on the server. Smart Security Manager Versions 1.4 and prior to 1.31 are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution.
-
CVE-2017-5169
•
published on February 13, 2017
An issue was discovered in Hanwha Techwin Smart Security Manager Versions 1.5 and prior. Multiple Cross Site Request Forgery vulnerabilities have been identified. The flaws exist within the Redis and Apache Felix Gogo servers that are installed as part of this product. By issuing specific HTTP Post requests, an attacker can gain system level access to a remote shell session. Smart Security Manager Versions 1.5 and prior are affected by these vulnerabilities. These vulnerabilities can allow for remote code execution.
-
CVE-2016-10224
•
published on February 13, 2017
An issue was discovered in Sauter NovaWeb web HMI. The application uses a protection mechanism that relies on the existence or values of a cookie, but it does not properly ensure that the cookie is valid for the associated user.