CVE-2016-8359
•
published on February 13, 2017
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).
-
CVE-2016-8361
•
published on February 13, 2017
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication.
-
CVE-2016-8370
•
published on February 13, 2017
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
-
CVE-2016-8378
•
published on February 13, 2017
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards for protecting credentials.
-
CVE-2016-8341
•
published on February 13, 2017
An issue was discovered in Ecava IntegraXor Version 5.0.413.0. The Ecava IntegraXor web server has parameters that are vulnerable to SQL injection. If the queries are not sanitized, the host's database could be subject to read, write, and delete commands.
-
CVE-2016-8356
•
published on February 13, 2017
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. The web server URL inputs are not sanitized correctly, which may allow cross-site scripting vulnerabilities.
-
CVE-2016-8360
•
published on February 13, 2017
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code.
-
CVE-2016-8368
•
published on February 13, 2017
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
-
CVE-2016-8372
•
published on February 13, 2017
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.
-
CVE-2016-8376
•
published on February 13, 2017
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. This non-validated redirect/non-validated forward (OPEN REDIRECT) allows chaining with authenticated vulnerabilities.
-
CVE-2016-8377
•
published on February 13, 2017
An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.
-
CVE-2016-8344
•
published on February 13, 2017
An issue was discovered in Honeywell Experion Process Knowledge System (PKS) platform: Experion PKS, Release 3xx and prior, Experion PKS, Release 400, Experion PKS, Release 410, Experion PKS, Release 430, and Experion PKS, Release 431. Experion PKS does not properly validate input. By sending a specially crafted packet, an attacker could cause the process to terminate. A successful exploit would prevent firmware uploads to the Series-C devices.
-
CVE-2016-8347
•
published on February 13, 2017
An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. WDC does not limit authentication attempts that may allow a brute force attack method.
-
CVE-2016-8364
•
published on February 13, 2017
An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that is available, a Heap-based Buffer Overflow.
-
CVE-2016-8374
•
published on February 13, 2017
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.
-
CVE-2016-8566
•
published on February 13, 2017
An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.
-
CVE-2016-8567
•
published on February 13, 2017
An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP.
-
CVE-2016-9347
•
published on February 13, 2017
An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily.
-
CVE-2016-9348
•
published on February 13, 2017
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext.
-
CVE-2016-9362
•
published on February 13, 2017
An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating.